Recommendation: Category G6
Recommendations on category G6
Test procedure for category G6:
NFC58-510 plus PPER (Combined test procedure, ageing ratio 1:1)
See Testprocedures and ref. [3])
As long as no results are available for this combined test procedure, select
the battery that has the best results (longest life time) for the two separate
test procedures.
Selection of battery and charge controller for category G6:
-
It is essential to use a charge controller that protects the battery both from
overcharging. The recommended end-of-charge-settings of the controller depend
on the type of battery and the category of battery usage. The recommended
batteries are given below, in order of preference, together with the
recommended voltage settings for the charge controllers at charging.
Recommended battery
in order of preference |
Controller settings(in V/cell at 25°C) |
maint.
months |
Flooded, industrial
flat plate with
electrolyte mixing |
Charge: 2.45 V (
2h / day)
Float 2.35 V
equalisation: 2.55 V (8 h / 2 weeks) |
6 |
| VRLA, flat plate
|
Charge: 2.45 V (2h / day)
Float 2.35 V
equalisation: 2.5 V (10h / month)
|
12 |
-
It is essential to use a charge controller that protects the battery both from
deep discharging. The control algorithm of the charge controller can be based
on a SoC calculation or on voltage settings. The recommended
end-of-discharge-settings of the controller are the following:
-
Low voltage Disconnect, for discharge current I10: 1.80 to 1.85 V/cell
-
Low voltage Disconnect, for discharge current 10% of I10: 1.95 to 2.0 V/cell
-
If the battery will be operated outside the temperature range of 20-30 degrees
it is preferable to use a charge controller that compensates for the effect of
the battery temperature. It will typically adjust settings to ensure that
charge and discharge cycles are modified based on temperature and voltage or
state of charge. A separate battery temperature sensor should be used.
-
It is preferable to use a charge controller with separate voltage sense
terminals.
More specific recommendations for category G6:
The main battery issue of category G6 is the low charge factor. To improve this
the following actions should be considered.
-
Apply the recommended values for the setpoints of the charge controller in the
table above.
-
Use a charge controller with a low self-consumption and with a high efficiency.
-
Reduce the load (e.g. by replacing appliances by more efficient ones).
-
Increase the electricity generation of the renewable energy sources.
-
Use (or increase the use of) a back-up generator. The most efficient way is to
use the back-up generator starting early in the morning and, once the threshold
voltage of the battery is reached and the power output of the back-up generator
is beginning to fall, continue charging the battery by means of the renewable
energy source.
-
Replace the battery with a battery of lower capacity if this is possible. Due
to the low charge factor, the capacity of the battery is likely to decrease
quickly and therefore a battery with a lower nominal capacity but proper charge
factor is likely to offer a better long-term security of supply.